Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Acta cir. bras ; 25(4): 337-341, July-Aug. 2010. ilus
Article in English | LILACS | ID: lil-553240

ABSTRACT

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Subject(s)
Animals , Female , Rats , Abdominal Wall/surgery , Implants, Experimental , Peritoneal Diseases/prevention & control , Peritoneum/drug effects , Polypropylenes/adverse effects , Surgical Mesh/adverse effects , Abdominal Wall/pathology , Biocompatible Materials , Foreign-Body Reaction/etiology , Foreign-Body Reaction/pathology , Inflammation/pathology , Peritoneal Diseases/etiology , Peritoneum/pathology , Polyhydroxyethyl Methacrylate/adverse effects , Rats, Wistar , Suture Techniques , Tissue Adhesions/pathology , Tissue Adhesions/prevention & control
2.
Korean Journal of Ophthalmology ; : 47-51, 2004.
Article in English | WPRIM | ID: wpr-70148

ABSTRACT

A 28-year-old female presented with a palpable mass lesion on the superonasal aspect of her right globe and she had a progressive diplopia. She had a scleral encircling surgery with a Miragel explant (MIRA, Waltham, Mass, USA) for the tractional retinal detachment associated with pars planitis 9 years previously. On examination, she revealed restricted eye movements of her right eye. The magnetic resonance imaging documented a swelling of the Miragel explant that mimicked a periorbital mass lesion. The Miragel explant was removed and fragmentation of the explant was found intraoperatively. The removed Miragel explant was examined by a scanning electron microscopy, and this demonstrated a disintergrated and swollen structural composition of the Miragel explant. Postoperatively, her extraocular movement was almost restored and the retina remained well attached. Alterations in the structural composition of the Miragel explant results in an excessive swelling that causes a restriction of the extraocular movement, and this can mimick a periorbital mass lesion.


Subject(s)
Adult , Female , Humans , Diplopia/etiology , Orbital Pseudotumor/etiology , Magnetic Resonance Imaging , Polyhydroxyethyl Methacrylate/adverse effects , Retinal Detachment/surgery , Scleral Buckling/adverse effects , Visual Fields